Loop Isolator—Analog
Universal signal conditioning module features 3-way isolation of analog signals and over 100 input and output analog conversion combinations. Power requirements: 11–36VDC, 3W max. or 24VAC, 50/60Hz, 4.8VA max, UL-recognized. (PN IT475)
Loop Isolator
Passive loop isolator, loop powered, Non-adjustable range/span, 0–20mA. Standard DIN rail mounting, slim 1/4” width. (PN IT476)
Rain Tipping Bucket
Corrosion resistant rainfall measuring device records rainfall measurements in 0.01” of rainfall. NOAA compliant. Requires Safe Module Plus (PN OP750). Rain tipping buckets must be level for accuracy. Refer to Rainfall Kit—MyDro-AC (PN KT278-SMP) for rainfall kit containing a mounting stand. (PN IT251)
Surge Suppressor—Analog
Surge suppressor for use with 4–20 mA loop circuits, 24V nominal line voltage. Replacement for surge suppressor included with non-submersible pressure transducer.
Transducer—Current
Converts AC current draw to a 4–20mA signal. Switchable current ranges (0–30, 0–60, 0–120amps); 4–20 mA out-
put, 30mA (max. draw) at 12–30 VDC sensor power, 5–140° F temp range, UL-listed. (PN IT484)
Transducer — Level, 0–15 ft, 40-ft Cable
Submersible, loop-powered, 2-wire transducer; 4–20 mA DC output over 0–6.5 PSI span (0–15 ft); 40-ft signal cable; Includes: sealed breather system and integral surge protector (PN IT470-1)
Transducer — Level, 0–23 ft, 40-ft Cable
Submersible, loop-powered, 2-wire transducer; 4–20 mA DC output over 0–10 PSI span (0–23.1 ft); 40-ft signal cable; Includes: sealed breather system and integral surge protector (PN IT470-2)
Transducer — Level, 0–23 ft, 65-ft Cable
Submersible, loop-powered, 2-wire transducer; 4–20 mA DC output over 0–10 PSI span (0-23.1 ft); 65-ft signal cable; Includes: sealed breather system and integral surge protector (PN IT470-3)
Transducer — Level, 0–23 ft, 55-ft Cable
Submersible, loop-powered, 2-wire transducer; 4–20 mA DC output over 0–6.5 PSI span (0-15 ft); 65-ft signal cable; Includes: sealed breather system and integral surge protector (PN IT470-4)
Transducer — Level, 0–15 ft, 65-ft Cable
Submersible, loop-powered, 2-wire transducer; 4–20 mA DC output over 0–6.5 PSI span (0-15 ft); 65-ft signal cable; Includes: sealed breather system and integral surge protector (PN IT470-5)
Transducer—Pressure, 0–15psi
316 stainless steel, non-submersible pressure transducer for use with ground tanks or water line pressure. 4–20mA, 0–34.65’ range, 18” cable. 0.20% accuracy, calibrated to produce industry-standard electrical outputs. Includes surge suppressor. (PN IT477S)
Transducer—Pressure, 0–30psi
316 stainless steel, non-submersible pressure transducer for use with elevated tanks or water line pressure. 4–20mA, 0–69.3’ range, 18” cable. (PN IT465S)
Transducer—Pressure, 0–75psi
316 stainless steel, non-submersible pressure transducer for use with elevated tanks or water line pressure. 4–20mA, 0–173.25’ range, 18” cable. (PN IT472S)
Transducer—Pressure, 0–50psi
316 Stainless steel, non-submersible pressure transducer for use with elevated tanks or water line pressure. 0–5V, 0–173.25’ range, 18” cable. Recommended for solar applications. Includes surge suppressor. (PN IT471S)
Transducer—Pressure, 0–150psi
316 Stainless steel, non-submersible pressure transducer for use with elevated tanks or water line pressure. 4–20 mA, 0–346.5’ range, 18” cable. 0.20% accuracy, calibrated to produce industry standard electrical outputs. Includes surge suppressor. (PN IT473S)
You’re Never Alone
You will receive experienced technical support, including access to the people that built the system if needed. This includes comprehensive training, regular webinars, live support during business hours and after-hours support that is always available on a responsive callback basis for emergencies—at no extra charge.